Reliably verify the calibration of your air leak or flow test system with a leak standard from CTS. Each leak master is made to order, precisely sized to the flow and pressure tolerances you specify. Our broad offering of mechanical connections make it easy to seamlessly integrate CTS air flow leak standards into existing systems. Manufactured in our A2LA accredited and ISO 17025 lab, we provide a calibration certificate traceable to NIST. You can trust a leak standard made by the experts in leak and flow testing!

Image of various CTS air flow leak standards angled and spread out.

Leak Orifices Specifications

Precision-manufactured leak orifices from CTS mount into master calibration parts or plug into test lines and manifolds for calibration processes.

Features include:

  • Leak or flow range: 1x10-5 atm-cc/sec to 50,000 scc/min
  • Leak and flow ranges manufactured to ISO 17025
  • Standard holder pressure range: -14.7 to 500 psig (-1.0 to 34.5 bar)
  • Welded holder pressure range: >500 to 3,000 psig (>34.5 to 206.8 bar)
  • Fully calibrated and NIST traceable
  • ISO 17025 A2LA accredited

ISO 17025 Certified Air Flow Leak Masters

1 Holder Type Leak Standard

Universal holder typically for in-line use. Inlet – 1/8” FNPT Outlet – 1/8” FNPT

1/8 MNPT Leak Standard

Universal holder typically used in a customer part. Inlet – 1/8” MNPT Outlet – N/A

1-2 Leak Standard

Universal holder typically for in-line use. Inlet – 1/8” FNPT Outlet – 1/8” MNPT

2 Leak Standard

Universal holder typically for in-line use. Inlet – 1/8” MNPT Outlet – 1/8” MNPT

21 Leak Standard

Holder designed to be used with the legacy I-21 instrument Inlet – ½”-20 w/ O-ring Outlet – N/A

2-1 Leak Standard

Universal holder typically for in-line use. Inlet – 1/8” MNPT Outlet – 1/8” FNPT

24 Leak Standard

Holder designed to be used with the C20WE, C28WE, I28 and some Blackbelt instruments as well as the legacy I-24. Inlet – 7/16”-20 w/ O-ring Outlet – N/A

24/10.32 Leak Standard

Holder designed to be used with the C20WE, C28WE, I28 and some Blackbelt instruments as well as the legacy I-24 that allows a 10-32 fitting connection on the outlet side. Inlet – 7/16”-20 w/ O-ring Outlet – 10-32

24R/10.32 Leak Standard

Holder designed to be used with the C20WE, C28WE, I28 and some Blackbelt instruments as well as the legacy I-24 that allows a 10-32 fitting connection on the outlet side where the flow direction is Reversed. Inlet – 7/16”-20 w/ O-ring Outlet – 10-32

3/8-16 Leak Standard

Holder designed with a specialized inlet with 3/8-16 threads Inlet – 3/8-16 Outlet – N/A

4CPC Leak Standard

Holder designed to plug directly into most standard instrument’s test port equipped with a Colder CPC ¼” female fitting. Inlet – Colder ¼” CPC Male Outlet – 1/8” FNPT

A Hold Type Leak Standard

Holder designed to plug into the Staubli RBE03 female fitting, commonly used on other leak testers as well as CTS leak testers. Inlet – Staubli RBE03 Male Outlet – N/A

AM 1/4 Leak Standard

Holder designed to plug into the Staubli RBE03 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Staubli RBE03 Male Outlet – ¼” Tube

AM Leak Standard

Holder designed to plug into the Staubli RBE03 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Staubli RBE03 Male Outlet – 1/8” FNPT

C20 Leak Standard

Holder designed to work with the legacy C-20 instrument as well as plug into a Colder CPC 1/8” female fitting Inlet – Colder 1/8” CPC Male Outlet – N/A

C20FC Leak Standard

Holder designed specifically to work with the legacy C-20 Cyclone instrument.

G Leak Standard

Universal holder that can be used for a variety of applications. Inlet – 1/8” FNPT Outlet – N/A

INT Leak Standard

Holder designed to plug into the Swagelok QM2 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Swagelok QM2 Male Outlet – 1/8” FNPT

KS4 Leak Standard

Holder designed to plug directly into a Festo KS4-1/4 female quick coupler. Inlet – Festo KS4-1/4 Male Outlet – N/A

M10 x 1.0 Leak Standard

Holder designed to replace the bleeder screw of a brake caliper housing. Inlet – M10x1.0 Outlet – N/A

M10 x 1.25 Leak Standard

Holder designed to thread into a M10x1.25 fitting Inlet – M10x1.25 Outlet – N/A

M10 x 1.5 Leak Standard

Holder designed to replace the bleeder screw of a brake caliper housing. Inlet – M10x1.5 Outlet – N/A

M12 x 1.25 Leak Standard

Holder designed with the crimped capillary epoxied into a drilled M12x1.25 set screw. Inlet – M12x1.25 Outlet – N/A

U Leak Standard

Holder designed to plug into the Swagelok QC4 female fitting, commonly used on other leak testers as well as CTS leak testers. Inlet – M12x1.25 Outlet – N/A

U2M 1/4 Leak Standard

Holder designed to plug into the Swagelok QM2 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Swagelok QM2 Male Outlet – ¼” Tube

UM 1/4" Leak Detection

Holder designed to plug into the Swagelok QC4 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Swagelok QC4 Male Outlet – ¼” Tube

UM Leak Detection

Holder designed to plug into the Swagelok QC4 female fitting, commonly used on other leak testers as well as CTS leak testers to allow for a connection on the outlet side. Inlet – Swagelok QC4 Male Outlet – 1/8” FNPT

Contact CTS for Air Flow Leak Standard Solutions

Contact CTS for a free evaluation of your leak standard requirements.