Documentation:

Sentinel Blackbelt™




Factory-installed options include CTS Connect actuator package and external leak standard orifice port. These options must be ordered with the instrument.


The Blackbelt is a precision benchtop leak test instrument designed for maximum performance and minimal space requirements. Cincinnati Test Systems' Blackbelt instrument utilizes advanced algorithms derived from over 30 years of proven leak test experience to produce the fast and accurate results required by the most demanding customers.

NEW Click here to view live demo

Advanced Standard Features

Configurable for the most common leak test applications
  • Pressure or vacuum decay (leak rate with embedded leak standard)
  • Pressure or vacuum change
  • Pressure or vacuum rate of change
  • Pressure or vacuum occlusion (blockage)
  • Pressure or vacuum burst test
  • Pressure or vacuum proof test
Powerful 32-bit processor & 24-bit A/D converter
  • Exceptionally fast, high-resolution test processing
  • Data resolution to 0.00001% of transducer full scale
Flexible communication formats
  • Ethernet
  • USB
  • RS232
Large full-color LCD display with graphing capability
  • User-friendly menus
  • Vivid pressure vs. time graphs
Patented Auto Setup feature for easy programming
  • One-touch teach
  • Can handle up to 99 programs (linkable)
Auto calibration
  • Ensures accurate results
  • Easy operation
Environmental drift correction
  • Adapts to changing conditions, including temperature
Quik test
  • Reduces test time
  • Analyzes test results in real time
Data storage
  • Last 5,000 tests stored in on-board memory, expandable through USB port
  • SPC data tracking for part traceability
Optional electronic regulation
  • High precision pressure control
  • Allows multiple pressure settings for successive tests
Self test functions
  • Internal leak check
  • Program calibration verification
  • Transducer calibration
Absolute pressure transducer
  • Absolute transducers are not influenced by environmental conditions.
Compact design
  • 11.25" high x 9"wide x 15" deep
  • Manifold-mounted valves, transducer and NIST traceable calibrated leak standard.
Download Adobe Reader

Acrobat® Reader® is required to view all pdf documents.